Metrix VX 0100 Electric Field Microwave Detector

Номер на артикул на RS: 740-6509Марка: Metrix№ по каталога на производителя: VX0100
brand-logo

Технически документи

Спецификации

Brand

Metrix

Radiation Type

Electric Field

Accuracy

±3% + 5 Digits

Power Source

Battery

Battery Life

60 → 80 h

Dimensions

63.6 x 40 x 163mm

Weight

200g

Height

163mm

Length

63.6mm

Maximum Frequency

100kHz

Minimum Frequency

3 kHz

Width

40mm

Model Number p

VX 0100

Страна на произход

France

Детайли за продукта

Bio Test® Low Frequency Electric Field Testers

The VX 0003 and VX 0100 electric field testers/meters instantly indicate the level of electromagnetic pollution. Ideal for the housing and tertiary sectors, they are designed for both professional and private use.

The Bio Test® VX testers are simple, economical, reliable and calibrated metrologically.
The VX 0003 (740-6506) is equipped with an internal antenna and can measure from 10 Hz to 3 kHz.
The VX 0100 (740-6509) has an interchangeable antenna for measurements from 10 Hz to 100 kHz.
The highly practical VX 0100 can also be used to detect cables during renovation work, for example.

Hand-held and designed for stand-alone use (60 to 80 hours)
Instruments designed by a well-known manufacturer in the electrical installation sector
Top-quality manufacture, professional instruments with 2-year warranty
Audio signal for immediate identification of field levels
Detailed manual for measurement, diagnostics and corrective solutions
Delivered with socket tester (phase position and presence of earth)

Supplied with

VX0003 (740-6506) supplied with with a 5 m earth cable (HX0103), socket tester, belt bag (HX0104).
VX0100 (740-6509) supplied with an external fi eld and cable detection antenna (HX0100), 5 m earth cable (HX0103), socket tester, hard case 270 x 195 x 65 (HX0109)

Standards

The VX 0003 and VX 0100 perform the test in accordance with the current and even future standards:
Recommendations by WHO / ICNIRP (World Health Organization / International Commission on Non-Ionizing Radiation Protection)
IEEE C95.6-2002 (International standard - Public, 0 - 3 kHz range)
European directive 1999/519/CE (Public, 0 - 100 kHz range and above)
European directive 2004/40/CE (Workers, 0 - 100 kHz range and above)
2010 draft standard, EN IEC 62493 (Lighting Systems)
EN50366 standard and IEC 62233 in 2012 (Household Appliances)

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

€ 345,19

Всеки (ex VAT)

Metrix VX 0100 Electric Field Microwave Detector

€ 345,19

Всеки (ex VAT)

Metrix VX 0100 Electric Field Microwave Detector
Информацията за складовите наличности временно не е налична.

Технически документи

Спецификации

Brand

Metrix

Radiation Type

Electric Field

Accuracy

±3% + 5 Digits

Power Source

Battery

Battery Life

60 → 80 h

Dimensions

63.6 x 40 x 163mm

Weight

200g

Height

163mm

Length

63.6mm

Maximum Frequency

100kHz

Minimum Frequency

3 kHz

Width

40mm

Model Number p

VX 0100

Страна на произход

France

Детайли за продукта

Bio Test® Low Frequency Electric Field Testers

The VX 0003 and VX 0100 electric field testers/meters instantly indicate the level of electromagnetic pollution. Ideal for the housing and tertiary sectors, they are designed for both professional and private use.

The Bio Test® VX testers are simple, economical, reliable and calibrated metrologically.
The VX 0003 (740-6506) is equipped with an internal antenna and can measure from 10 Hz to 3 kHz.
The VX 0100 (740-6509) has an interchangeable antenna for measurements from 10 Hz to 100 kHz.
The highly practical VX 0100 can also be used to detect cables during renovation work, for example.

Hand-held and designed for stand-alone use (60 to 80 hours)
Instruments designed by a well-known manufacturer in the electrical installation sector
Top-quality manufacture, professional instruments with 2-year warranty
Audio signal for immediate identification of field levels
Detailed manual for measurement, diagnostics and corrective solutions
Delivered with socket tester (phase position and presence of earth)

Supplied with

VX0003 (740-6506) supplied with with a 5 m earth cable (HX0103), socket tester, belt bag (HX0104).
VX0100 (740-6509) supplied with an external fi eld and cable detection antenna (HX0100), 5 m earth cable (HX0103), socket tester, hard case 270 x 195 x 65 (HX0109)

Standards

The VX 0003 and VX 0100 perform the test in accordance with the current and even future standards:
Recommendations by WHO / ICNIRP (World Health Organization / International Commission on Non-Ionizing Radiation Protection)
IEEE C95.6-2002 (International standard - Public, 0 - 3 kHz range)
European directive 1999/519/CE (Public, 0 - 100 kHz range and above)
European directive 2004/40/CE (Workers, 0 - 100 kHz range and above)
2010 draft standard, EN IEC 62493 (Lighting Systems)
EN50366 standard and IEC 62233 in 2012 (Household Appliances)