Технически документи
Спецификации
Brand
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
48V dc
Number of Outputs
2
Mount Type
Panel
Power
400W
Minimum Operating Temperature
-20°C
SMPS Output Current
5.21A
Maximum Operating Temperature
70°C
Depth
198mm
Weight
440g
Standards/Approvals
IEC 61000-4-8 (lv 4), IEC/UL/CSA/EN 62368-1, IEC 61000-4-4 (lv 3), IEC 61000-4-5 (lv 3,4), IEC 61000-4-6 (lv 3), CE, EN 55022-B, FCC-B, IEC 61000-4-11, IEC 61000-4-2 (lv 2,3), IEC 61000-4-3 (lv3)
Width
128mm
Length
198mm
Efficiency
90%
Maximum Input Voltage
264V ac
Series
CUS400M
Output Current
5.21A
Hazardous Area Certification
No
Minimum Input Voltage
85V ac
Страна на произход
United Kingdom
Детайли за продукта
The TDK-Lambda compact CUS400M is packaged in the industry standard 3x5 footprint. The series can deliver 400W with forced air or 250W when convection cooled with a 400W peak power for extended periods of time (minutes). Cooling is also assisted via conduction through the base into the equipment chassis. With Medical & ITE certifications, the units can be used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. Options include a standby voltage, signalling and multiple case options.
Информацията за складовите наличности временно не е налична.
€ 230,63
€ 230,63 Всеки (ex VAT)
1
€ 230,63
€ 230,63 Всеки (ex VAT)
Информацията за складовите наличности временно не е налична.
1
| количество | Единична цена |
|---|---|
| 1 - 4 | € 230,63 |
| 5 - 9 | € 223,70 |
| 10 - 24 | € 216,79 |
| 25 - 49 | € 209,87 |
| 50+ | € 202,94 |
Технически документи
Спецификации
Brand
TDK-LambdaProduct Type
Switching Power Supply
Maximum Output Voltage
48V dc
Number of Outputs
2
Mount Type
Panel
Power
400W
Minimum Operating Temperature
-20°C
SMPS Output Current
5.21A
Maximum Operating Temperature
70°C
Depth
198mm
Weight
440g
Standards/Approvals
IEC 61000-4-8 (lv 4), IEC/UL/CSA/EN 62368-1, IEC 61000-4-4 (lv 3), IEC 61000-4-5 (lv 3,4), IEC 61000-4-6 (lv 3), CE, EN 55022-B, FCC-B, IEC 61000-4-11, IEC 61000-4-2 (lv 2,3), IEC 61000-4-3 (lv3)
Width
128mm
Length
198mm
Efficiency
90%
Maximum Input Voltage
264V ac
Series
CUS400M
Output Current
5.21A
Hazardous Area Certification
No
Minimum Input Voltage
85V ac
Страна на произход
United Kingdom
Детайли за продукта
The TDK-Lambda compact CUS400M is packaged in the industry standard 3x5 footprint. The series can deliver 400W with forced air or 250W when convection cooled with a 400W peak power for extended periods of time (minutes). Cooling is also assisted via conduction through the base into the equipment chassis. With Medical & ITE certifications, the units can be used in both Class I & Class II (no ground wire) applications, and meets Class B Conducted and Radiated EMI. Options include a standby voltage, signalling and multiple case options.