Phoenix Contact PSR-SPP- 24UC/SDC4/2X1/B Emergency Stop Safety Relay, 24V dc, Dual-Channel, 2 Safety Contacts

Номер на артикул на RS: 666-7069Марка: Phoenix Contact№ по каталога на производителя: 2981499
brand-logo
Преглед на всички в Предпазни релета

Технически документи

Спецификации

Supply Voltage

24V dc

Number of Channels

2

Safety Contacts

2

Function

Emergency Stop

Auxiliary Contacts

1

Range

PSRclassic

Safety Category ISO 13849-1

4

PL ISO 13849-1

e

SIL IEC 61508

3

Terminal Type

Screw

Configurable

No

Series

PSR-SPP- 24UC/SDC4/2X1/B

Width

22.5mm

Depth

114.5mm

Performance Level

e

Length

112mm

Страна на произход

Germany

Детайли за продукта

Multi-application Modular System - PSR Series

The PSR safety relays from Phoenix contacts can be quickly and reliably assembled to form a tailor-made safety solution.
To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The interface module is used for the connection of up to four safety sensors with NC/NO contacts to the safety relay PSR-SDC4, with screw connection.

Features and Benefits

• Quick system extension up to 10 modules, offering a safety system with up to 42 contacts
• Automatic identification of desired operating mode, no need to set switches or define parameters
• The system is based on a master relay (PSR-SDC) that monitors e-stops, guard doors (interlock or non-contact) and optical devices (e.g. light curtains)
• Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple
• 24Vdc supply voltage
• Semiconductor output
• Depending on the wiring Safety category 2 or 4 can be maintained
• One or Two channel switches are used for control

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

€ 222,45

Всеки (ex VAT)

Phoenix Contact PSR-SPP- 24UC/SDC4/2X1/B Emergency Stop Safety Relay, 24V dc, Dual-Channel, 2 Safety Contacts

€ 222,45

Всеки (ex VAT)

Phoenix Contact PSR-SPP- 24UC/SDC4/2X1/B Emergency Stop Safety Relay, 24V dc, Dual-Channel, 2 Safety Contacts
Информацията за складовите наличности временно не е налична.

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more

Технически документи

Спецификации

Supply Voltage

24V dc

Number of Channels

2

Safety Contacts

2

Function

Emergency Stop

Auxiliary Contacts

1

Range

PSRclassic

Safety Category ISO 13849-1

4

PL ISO 13849-1

e

SIL IEC 61508

3

Terminal Type

Screw

Configurable

No

Series

PSR-SPP- 24UC/SDC4/2X1/B

Width

22.5mm

Depth

114.5mm

Performance Level

e

Length

112mm

Страна на произход

Germany

Детайли за продукта

Multi-application Modular System - PSR Series

The PSR safety relays from Phoenix contacts can be quickly and reliably assembled to form a tailor-made safety solution.
To connect using TBUS correctly you will need one PSR-TBUS per module. For the last additional module use one PSR-TBUS-TP instead, this will close the feedback loop. The interface module is used for the connection of up to four safety sensors with NC/NO contacts to the safety relay PSR-SDC4, with screw connection.

Features and Benefits

• Quick system extension up to 10 modules, offering a safety system with up to 42 contacts
• Automatic identification of desired operating mode, no need to set switches or define parameters
• The system is based on a master relay (PSR-SDC) that monitors e-stops, guard doors (interlock or non-contact) and optical devices (e.g. light curtains)
• Safe cross-wiring with T-BUS renders the usual cross-wiring of supply voltage, enable signal and confirmation path redundant. Making commissioning and future expansion simple
• 24Vdc supply voltage
• Semiconductor output
• Depending on the wiring Safety category 2 or 4 can be maintained
• One or Two channel switches are used for control

Ideate. Create. Collaborate

JOIN FOR FREE

No hidden fees!

design-spark
design-spark
  • Download and use our DesignSpark software for your PCB and 3D Mechanical designs
  • View and contribute website content and forums
  • Download 3D Models, Schematics and Footprints from more than a million products
Click here to find out more