Norgren 04 series 0.2ms to 0.4ms Pneumatic Timer, 10 bar max

Номер на артикул на RS: 777-126Марка: Norgren№ по каталога на производителя: 04043102000
brand-logo

Технически документи

Спецификации

Brand

Norgren

Maximum Time

0.4ms

Minimum Time

0.2ms

Maximum Operating Temperature

+80°C

Manufacturer Series

04

Minimum Operating Pressure

2bar

Maximum Operating Pressure

10 bar

Minimum Operating Temperature

-20°C

Страна на произход

United Kingdom

Детайли за продукта

Impulse Generator

Fitted between a trip valve and directional control valve when it is necessary to eliminate a trapped or locked pilot signal that would otherwise prevent the control valve from resetting. When an input signal is applied, it generates a short duration output signal, which is then automatically exhausted. A further output signal cannot be generated until the input signal has been removed
Will provide an output signal pressure of 90% of the input pressure. The downstream volume of the tubing and pilot chamber of the control valve should not exceed 0.033 dm3. This volume is equivalent to approximately 6.5 metres of 4mm o/d nylon tube
Impulse duration 0.2 - 0.4s

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

€ 198,70

Всеки (ex VAT)

Norgren 04 series 0.2ms to 0.4ms Pneumatic Timer, 10 bar max

€ 198,70

Всеки (ex VAT)

Norgren 04 series 0.2ms to 0.4ms Pneumatic Timer, 10 bar max
Информацията за складовите наличности временно не е налична.

Купете в насипно състояние

количествоЕдинична цена
1 - 4€ 198,70
5+€ 192,75

Технически документи

Спецификации

Brand

Norgren

Maximum Time

0.4ms

Minimum Time

0.2ms

Maximum Operating Temperature

+80°C

Manufacturer Series

04

Minimum Operating Pressure

2bar

Maximum Operating Pressure

10 bar

Minimum Operating Temperature

-20°C

Страна на произход

United Kingdom

Детайли за продукта

Impulse Generator

Fitted between a trip valve and directional control valve when it is necessary to eliminate a trapped or locked pilot signal that would otherwise prevent the control valve from resetting. When an input signal is applied, it generates a short duration output signal, which is then automatically exhausted. A further output signal cannot be generated until the input signal has been removed
Will provide an output signal pressure of 90% of the input pressure. The downstream volume of the tubing and pilot chamber of the control valve should not exceed 0.033 dm3. This volume is equivalent to approximately 6.5 metres of 4mm o/d nylon tube
Impulse duration 0.2 - 0.4s