Megger MIT230 Insulation & Continuity Tester, 250V dc Min, 1000V dc Max, 999MΩ Max, CAT III 300V - UKAS Calibration

Номер на артикул на RS: 535-6493Марка: Megger№ по каталога на производителя: MIT230-EN
brand-logo

Технически документи

Спецификации

Brand

Megger

Model Number p

MIT230

Model Number (p)

MIT230

Tester Type

Insulation & Continuity Tester

Maximum Test Voltage

1000V dc

Minimum Test Voltage

250V dc

Maximum Insulation Resistance Measurement

999mΩ

Display Type

LCD

Calibrated

UKAS

Test Current

200mA

Power Source

Battery

Battery Life

3000 5-Second Tests

Battery Type

AA

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

+55°C

Safety Category Level

CAT III

Safety Category Voltage

300V

Safety Category

CAT III 300V

Weight

530g

Width

98mm

Length

195mm

Dimensions

195 x 98 x 40mm

Height

40mm

Страна на произход

United Kingdom

Детайли за продукта

MIT230 Insulation & Continuity Tester

The MIT230 incorporates a range of safety and operation features in one of the smallest electrical insulation testers available. Its LCD offers a combination of digital readout and analogue display, with an analogue pointer response for evaluating circuit charge and discharge characteristics. The instrument housing is in tough ABS.

Features & Benefits

Insulation testing to 1000 MΩ
Dual & triple test voltages models
Digital display with electronic analogue arc display helps to confirm insulation condition & to monitor fluctuating readings not apparent on the digital display
Continuity testing at 200 mA down to 0.01 Ω resolution
Automatic discharge of circuit under test
1 mA test current at selected voltage range
Default voltmeter automatically switches in when the instrument is connected to a circuit with an AC or DC voltage greater than 25 V
Auto-ranging analogue arc scale shows only the scale in use
Live circuit warning above 25 V, also inhibits insulation & continuity tests above 50 V
Lead resistance compensation on continuity
Hands free continuity testing Auto power-down after 5 min
Complies with IEC 1010-1 safety standard installation Category III, 600 V phase to earth
Conforms to EN61557-1
Tests to BS7671, 713-02, 713-03, 713-04, 713-06, 713-08, 413-04-04

Supplied with

6 x AA alkaline batteries, test leads, crocodile clips, carry case, instructions

Warning

When measuring voltages, the use of fused test leads is recommended for personal safety.

Може да се интересувате от

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

€ 765,39

Всеки (ex VAT)

Megger MIT230 Insulation & Continuity Tester, 250V dc Min, 1000V dc Max, 999MΩ Max, CAT III 300V - UKAS Calibration

Calibration type

€ 765,39

Всеки (ex VAT)

Megger MIT230 Insulation & Continuity Tester, 250V dc Min, 1000V dc Max, 999MΩ Max, CAT III 300V - UKAS Calibration
Информацията за складовите наличности временно не е налична.

Calibration type

Може да се интересувате от

Технически документи

Спецификации

Brand

Megger

Model Number p

MIT230

Model Number (p)

MIT230

Tester Type

Insulation & Continuity Tester

Maximum Test Voltage

1000V dc

Minimum Test Voltage

250V dc

Maximum Insulation Resistance Measurement

999mΩ

Display Type

LCD

Calibrated

UKAS

Test Current

200mA

Power Source

Battery

Battery Life

3000 5-Second Tests

Battery Type

AA

Minimum Operating Temperature

-10°C

Maximum Operating Temperature

+55°C

Safety Category Level

CAT III

Safety Category Voltage

300V

Safety Category

CAT III 300V

Weight

530g

Width

98mm

Length

195mm

Dimensions

195 x 98 x 40mm

Height

40mm

Страна на произход

United Kingdom

Детайли за продукта

MIT230 Insulation & Continuity Tester

The MIT230 incorporates a range of safety and operation features in one of the smallest electrical insulation testers available. Its LCD offers a combination of digital readout and analogue display, with an analogue pointer response for evaluating circuit charge and discharge characteristics. The instrument housing is in tough ABS.

Features & Benefits

Insulation testing to 1000 MΩ
Dual & triple test voltages models
Digital display with electronic analogue arc display helps to confirm insulation condition & to monitor fluctuating readings not apparent on the digital display
Continuity testing at 200 mA down to 0.01 Ω resolution
Automatic discharge of circuit under test
1 mA test current at selected voltage range
Default voltmeter automatically switches in when the instrument is connected to a circuit with an AC or DC voltage greater than 25 V
Auto-ranging analogue arc scale shows only the scale in use
Live circuit warning above 25 V, also inhibits insulation & continuity tests above 50 V
Lead resistance compensation on continuity
Hands free continuity testing Auto power-down after 5 min
Complies with IEC 1010-1 safety standard installation Category III, 600 V phase to earth
Conforms to EN61557-1
Tests to BS7671, 713-02, 713-03, 713-04, 713-06, 713-08, 413-04-04

Supplied with

6 x AA alkaline batteries, test leads, crocodile clips, carry case, instructions

Warning

When measuring voltages, the use of fused test leads is recommended for personal safety.