Supply Voltage

24V ac/dc

Number of Channels

1

Safety Contacts

3

Function

Safety Switch/Interlock

Auxiliary Contacts

2

Range

Minotaur

Terminal Type

Screw

Series

MSR8T

Width

73mm

Safety Category

3

Depth

45.5mm

Length

120mm

Страна на произход

United Kingdom

Детайли за продукта

Minotaur MSR8T, Single Channel or Extension Unit

Ensures correct switching of up to 3 contactors with monitoring
Fail-safe internal monitoring
Single channel input for use with interlock switches and emergency stop buttons. 3 uncommitted safety output circuits and provides a contactor monitoring facility and auxiliary output for indication purposes
Power failure on safety critical internal faults result in a lock-out to a safe state
Can also be used as an extension unit for other devices. When inputs are connected to one of the outputs on the host unit, the MSR8T will mimic the outputs on the host unit

Standards

EN 60204-1; EN 292; EN 954-1

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

P.O.A.

Allen Bradley Guardmaster MSR8T Safety Relay, 24V ac/dc, Single Channel, 3 Safety Contacts

P.O.A.

Allen Bradley Guardmaster MSR8T Safety Relay, 24V ac/dc, Single Channel, 3 Safety Contacts
Информацията за складовите наличности временно не е налична.

Технически документи

Спецификации

Supply Voltage

24V ac/dc

Number of Channels

1

Safety Contacts

3

Function

Safety Switch/Interlock

Auxiliary Contacts

2

Range

Minotaur

Terminal Type

Screw

Series

MSR8T

Width

73mm

Safety Category

3

Depth

45.5mm

Length

120mm

Страна на произход

United Kingdom

Детайли за продукта

Minotaur MSR8T, Single Channel or Extension Unit

Ensures correct switching of up to 3 contactors with monitoring
Fail-safe internal monitoring
Single channel input for use with interlock switches and emergency stop buttons. 3 uncommitted safety output circuits and provides a contactor monitoring facility and auxiliary output for indication purposes
Power failure on safety critical internal faults result in a lock-out to a safe state
Can also be used as an extension unit for other devices. When inputs are connected to one of the outputs on the host unit, the MSR8T will mimic the outputs on the host unit

Standards

EN 60204-1; EN 292; EN 954-1