SolaHD 20kVA Chassis Mounting Transformer, 133V ac

Номер на артикул на RS: 890-8693Марка: SolaHD№ по каталога на производителя: DT661H20S
brand-logo

Технически документи

Спецификации

Brand

SolaHD

Primary Voltage Rating

460V ac

Secondary Voltage Rating

133 V ac, 230V ac

Power Rating

20kVA

Mounting Type

Panel Mount

Width

18in

Depth

14in

Dimensions

23 x 18 x 14in

Weight

210lb

Maximum Operating Frequency

60Hz

Страна на произход

United States

Детайли за продукта

SolaHD Drive Isolation Transformers - DT Series

Drive isolation transformers from SolaHD. DT series of transformer is designed to handle the mechanical stress, voltage demands and harmonics associated with SCR (Silicon Control Rectifier) variable speed motor drive applications. The transformer must offer a voltage change to match the required voltage of the SCR Drive. Available in a 3 phase unit from 7.5 kVA to 440 kVA.

Available from 7.5 kVA → 440 kVA, 3 Phase, 60 Hz
Isolation minimises load disturbances caused by the SCR drive
Taps on all units for adjustment to incoming source voltage
Shielding attenuates line to ground noise
UL 3R enclosures when used with optional weather shield
UL Listed

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

€ 1 727,05

Всеки (ex VAT)

SolaHD 20kVA Chassis Mounting Transformer, 133V ac

€ 1 727,05

Всеки (ex VAT)

SolaHD 20kVA Chassis Mounting Transformer, 133V ac
Информацията за складовите наличности временно не е налична.

Технически документи

Спецификации

Brand

SolaHD

Primary Voltage Rating

460V ac

Secondary Voltage Rating

133 V ac, 230V ac

Power Rating

20kVA

Mounting Type

Panel Mount

Width

18in

Depth

14in

Dimensions

23 x 18 x 14in

Weight

210lb

Maximum Operating Frequency

60Hz

Страна на произход

United States

Детайли за продукта

SolaHD Drive Isolation Transformers - DT Series

Drive isolation transformers from SolaHD. DT series of transformer is designed to handle the mechanical stress, voltage demands and harmonics associated with SCR (Silicon Control Rectifier) variable speed motor drive applications. The transformer must offer a voltage change to match the required voltage of the SCR Drive. Available in a 3 phase unit from 7.5 kVA to 440 kVA.

Available from 7.5 kVA → 440 kVA, 3 Phase, 60 Hz
Isolation minimises load disturbances caused by the SCR drive
Taps on all units for adjustment to incoming source voltage
Shielding attenuates line to ground noise
UL 3R enclosures when used with optional weather shield
UL Listed