RS PRO LED Emergency Lighting, Twin Spot, 2 x 3 W, Non Maintained

Номер на артикул на RS: 795-9766Марка: RS PRO
brand-logo

Технически документи

Спецификации

Brand

RS Pro

Maintained

Non Maintained

Length

300 mm

Width

297 mm

Depth

73 mm

Lamp Type

LED

Wattage

2 x 3 W

IP Rating

IP65

Fitting Type

Twin Spot

Luminosity

340 lm

Lamp Supplied

Yes

Duration

3h

Voltage Rating

230 V

Страна на произход

China

Детайли за продукта

RS PRO Emergency IP65 LED Twin-spot Non-maintained Luminaire

This IP65 LED non-maintained twin-spot luminaire features a lightweight polycarbonate body with twin-spots LED lamps. This LED emergency luminaire offers an energy saving and cost effective solution to fulfil emergency lighting requirements. Ideal for places requiring an emergency lighting supply like industrial units and warehouses.

LEDs produce a high-quality white light and offer a long shelf life, they’re also easy to replace.

In the event of an emergency, our RS PRO range of emergency lighting means that you have the right lighting to illuminate exits. The whole range is RS approved meaning that they are great value for money and high quality you can rely on.

Features and Benefits:

2 x 3W LED
3.6V 600mAh NiCd
Total lumen output 340 lm
Lamps ok status and Charge indicators
3-hour non-maintained operation on battery power
Polycarbonate IP65 body
Lightweight, only 2.8Kg
IP65 rated - protected against dust that may harm equipment, and protected against water spray

Typical Applications:

This LED emergency twin-spot light is ideal for industrial applications and can be found in:
· Corridors
· Warehouses

FAQs

What is the difference between maintained and non-maintained emergency lighting?
Maintained emergency lighting's purpose is to be lit continuously and will stay lit when there is a power failure or an emergency such as a fire. A maintained emergency light will allow the pathways or areas to be permanently illuminated and usually helps guide people to exit signs and safety. Sometimes these types of lighting solutions can double up as a normal light fitting.
Non-maintained emergency lighting has been designed to switch on in the instance of an emergency or power outage to help provide lighting to people who need to make their way to an exit or to follow an escape route. This kind of lighting solution provides a battery backup light source.

Why is Emergency Lighting so important?
It is essential that all occupied buildings should have escape lighting to allow for safe exit should mains power fail. Emergencies luminaires have fitted back up batteries which are continuously charged during standard operation and have at least 3 hours of power. Lights must be installed to provide sufficient illumination according to the different areas of premises and must conform to the latest legislation.

Emergency Light Fittings

There are two basic types of emergency lighting luminaires - maintained and non-maintained.
Maintained, these luminaires have the advantage of being able to be switched between the maintained function (lamp illuminated at all times) and non-maintained (lamp off until power supply fails), making them ideal for applications such as corridors, workshops and permanently illuminated emergency exit signs. The maintained luminaires also have the facility of being switched in banks of up to ten units.

Non-maintained, these luminaires are only illuminated on a failure of the mains supply. Ideal for emergency exits, switchrooms and storage areas.

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

P.O.A.

RS PRO LED Emergency Lighting, Twin Spot, 2 x 3 W, Non Maintained

P.O.A.

RS PRO LED Emergency Lighting, Twin Spot, 2 x 3 W, Non Maintained
Информацията за складовите наличности временно не е налична.

Технически документи

Спецификации

Brand

RS Pro

Maintained

Non Maintained

Length

300 mm

Width

297 mm

Depth

73 mm

Lamp Type

LED

Wattage

2 x 3 W

IP Rating

IP65

Fitting Type

Twin Spot

Luminosity

340 lm

Lamp Supplied

Yes

Duration

3h

Voltage Rating

230 V

Страна на произход

China

Детайли за продукта

RS PRO Emergency IP65 LED Twin-spot Non-maintained Luminaire

This IP65 LED non-maintained twin-spot luminaire features a lightweight polycarbonate body with twin-spots LED lamps. This LED emergency luminaire offers an energy saving and cost effective solution to fulfil emergency lighting requirements. Ideal for places requiring an emergency lighting supply like industrial units and warehouses.

LEDs produce a high-quality white light and offer a long shelf life, they’re also easy to replace.

In the event of an emergency, our RS PRO range of emergency lighting means that you have the right lighting to illuminate exits. The whole range is RS approved meaning that they are great value for money and high quality you can rely on.

Features and Benefits:

2 x 3W LED
3.6V 600mAh NiCd
Total lumen output 340 lm
Lamps ok status and Charge indicators
3-hour non-maintained operation on battery power
Polycarbonate IP65 body
Lightweight, only 2.8Kg
IP65 rated - protected against dust that may harm equipment, and protected against water spray

Typical Applications:

This LED emergency twin-spot light is ideal for industrial applications and can be found in:
· Corridors
· Warehouses

FAQs

What is the difference between maintained and non-maintained emergency lighting?
Maintained emergency lighting's purpose is to be lit continuously and will stay lit when there is a power failure or an emergency such as a fire. A maintained emergency light will allow the pathways or areas to be permanently illuminated and usually helps guide people to exit signs and safety. Sometimes these types of lighting solutions can double up as a normal light fitting.
Non-maintained emergency lighting has been designed to switch on in the instance of an emergency or power outage to help provide lighting to people who need to make their way to an exit or to follow an escape route. This kind of lighting solution provides a battery backup light source.

Why is Emergency Lighting so important?
It is essential that all occupied buildings should have escape lighting to allow for safe exit should mains power fail. Emergencies luminaires have fitted back up batteries which are continuously charged during standard operation and have at least 3 hours of power. Lights must be installed to provide sufficient illumination according to the different areas of premises and must conform to the latest legislation.

Emergency Light Fittings

There are two basic types of emergency lighting luminaires - maintained and non-maintained.
Maintained, these luminaires have the advantage of being able to be switched between the maintained function (lamp illuminated at all times) and non-maintained (lamp off until power supply fails), making them ideal for applications such as corridors, workshops and permanently illuminated emergency exit signs. The maintained luminaires also have the facility of being switched in banks of up to ten units.

Non-maintained, these luminaires are only illuminated on a failure of the mains supply. Ideal for emergency exits, switchrooms and storage areas.