Roxburgh EMC, DVS Surge Suppressor Unit 56 V dc, 40V ac Maximum Voltage Rating 40 kA Maximum Surge Current Type 2

Номер на артикул на RS: 707-9814Марка: Roxburgh EMC№ по каталога на производителя: DVSC2440
brand-logo

Технически документи

Спецификации

Product Type

Surge Suppressor Unit

Suppressor Type

Type 2 Arrester, Type 1 Arrester

Maximum Voltage

56, 40V dc

Mount Type

DIN Rail

Maximum Surge Current

40kA

Series

DVS

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

80°C

Length

35mm

Height

90mm

Depth

68mm

Standards/Approvals

RoHS

Hazardous Area Certification

No

Детайли за продукта

MOV Module, DVS Series

Modular slim-line transient voltage suppressors designed to snap-fit directly onto top hat profile DIN rails.

Dual high-energy electrically isolated metal oxide varistors
Fuse protection from line surges

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Информацията за складовите наличности временно не е налична.

€ 129,70

€ 129,70 Всеки (ex VAT)

Roxburgh EMC, DVS Surge Suppressor Unit 56 V dc, 40V ac Maximum Voltage Rating 40 kA Maximum Surge Current Type 2

€ 129,70

€ 129,70 Всеки (ex VAT)

Roxburgh EMC, DVS Surge Suppressor Unit 56 V dc, 40V ac Maximum Voltage Rating 40 kA Maximum Surge Current Type 2

Информацията за складовите наличности временно не е налична.

количествоЕдинична цена
1 - 1€ 129,70
2 - 4€ 124,51
5+€ 118,02

Технически документи

Спецификации

Product Type

Surge Suppressor Unit

Suppressor Type

Type 2 Arrester, Type 1 Arrester

Maximum Voltage

56, 40V dc

Mount Type

DIN Rail

Maximum Surge Current

40kA

Series

DVS

Minimum Operating Temperature

-40°C

Maximum Operating Temperature

80°C

Length

35mm

Height

90mm

Depth

68mm

Standards/Approvals

RoHS

Hazardous Area Certification

No

Детайли за продукта

MOV Module, DVS Series

Modular slim-line transient voltage suppressors designed to snap-fit directly onto top hat profile DIN rails.

Dual high-energy electrically isolated metal oxide varistors
Fuse protection from line surges

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.