P.M.A TB 40-1 PID Temperature Controller, 96 x 48 (1/8 DIN)mm, 3 Output Relay, 90 → 250 V ac Supply Voltage

Номер на артикул на RS: 736-4749Марка: P.M.A№ по каталога на производителя: TB40-100-0000D-000
brand-logo

Технически документи

Спецификации

Brand

P.M.A

Output Type

Relay

Supply Voltage

90 → 250 V ac

Size

96 x 48 (1/8 DIN)mm

Number of Outputs

3

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

+65°C

Temperature Range

0 → +1760 (Type R Thermocouple) °C, 0 → +1760 (Type S Thermocouple) °C, 0 → +1820 (Type B Thermocouple) °C, 0 → +2315 (Type C Thermocouple) °C, 0 → +2315 (Type D Thermocouple) °C, -100 → +1000 (Type E Thermocouple) °C, -100 → +1200 (Type J Thermocouple) °C, -100 → +1300 (Type N Thermocouple) °C, -100 → +1350 (Type K Thermocouple) °C, -100 → +900 (Type L Thermocouple) °C, -200 → +200 (PT1000) °C, -200 → +400 (Type T Thermocouple) °C, -200 → +850 (PT100) °C

Display Type

LED, Multi Line

IP Rating

IP00, IP20, IP65

Series

TB 40-1

Panel Depth

118mm

Страна на произход

United Kingdom

Детайли за продукта

PMA TB 40-1 Limit Controller

The TB 40-1 limit controller has been type tested to DIN standards.

The TB40-1 can be used for heating and refrigeration processes. It is suitable for all thermocouple types and resistance type sensors. It is particularly designed for use in all applications where an over or under temperature fault condition could present fire hazard or other hazard, heating system in buildings to DIN EN 12828, large hot-water boilers to DIN EN 12953-6, thermal transfer plants with organic heat transfer media to DIN 4754 and oil-fired installations to DIN 4755.

• Applicable for heating and cooling applications
• For all types of thermocouples and resistance transducers
• BluePort Front interface and BlueControl Software
• Maintenance manager and error list
• Alarm reset via RESET-key
• Alarm reset via digital
• Type tested to EN 14597 and cULus

PMA Temperature Controllers

Информацията за складовите наличности временно не е налична.

€ 486,72

€ 486,72 Всеки (ex VAT)

P.M.A TB 40-1 PID Temperature Controller, 96 x 48 (1/8 DIN)mm, 3 Output Relay, 90 → 250 V ac Supply Voltage

€ 486,72

€ 486,72 Всеки (ex VAT)

P.M.A TB 40-1 PID Temperature Controller, 96 x 48 (1/8 DIN)mm, 3 Output Relay, 90 → 250 V ac Supply Voltage
Информацията за складовите наличности временно не е налична.

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Технически документи

Спецификации

Brand

P.M.A

Output Type

Relay

Supply Voltage

90 → 250 V ac

Size

96 x 48 (1/8 DIN)mm

Number of Outputs

3

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

+65°C

Temperature Range

0 → +1760 (Type R Thermocouple) °C, 0 → +1760 (Type S Thermocouple) °C, 0 → +1820 (Type B Thermocouple) °C, 0 → +2315 (Type C Thermocouple) °C, 0 → +2315 (Type D Thermocouple) °C, -100 → +1000 (Type E Thermocouple) °C, -100 → +1200 (Type J Thermocouple) °C, -100 → +1300 (Type N Thermocouple) °C, -100 → +1350 (Type K Thermocouple) °C, -100 → +900 (Type L Thermocouple) °C, -200 → +200 (PT1000) °C, -200 → +400 (Type T Thermocouple) °C, -200 → +850 (PT100) °C

Display Type

LED, Multi Line

IP Rating

IP00, IP20, IP65

Series

TB 40-1

Panel Depth

118mm

Страна на произход

United Kingdom

Детайли за продукта

PMA TB 40-1 Limit Controller

The TB 40-1 limit controller has been type tested to DIN standards.

The TB40-1 can be used for heating and refrigeration processes. It is suitable for all thermocouple types and resistance type sensors. It is particularly designed for use in all applications where an over or under temperature fault condition could present fire hazard or other hazard, heating system in buildings to DIN EN 12828, large hot-water boilers to DIN EN 12953-6, thermal transfer plants with organic heat transfer media to DIN 4754 and oil-fired installations to DIN 4755.

• Applicable for heating and cooling applications
• For all types of thermocouples and resistance transducers
• BluePort Front interface and BlueControl Software
• Maintenance manager and error list
• Alarm reset via RESET-key
• Alarm reset via digital
• Type tested to EN 14597 and cULus

PMA Temperature Controllers