Phoenix Contact 1 Channel Galvanic Barrier, ATEX

Номер на артикул на RS: 751-1380Марка: Phoenix Contact№ по каталога на производителя: 2924799
brand-logo

Технически документи

Спецификации

Number of Channels

1

Barrier Type

Galvanic Barrier

Maximum Voltage

125 V dc, 253V ac

Hazardous Area Certification

ATEX

Supply Voltage

24 → 230V ac/dc

Maximum Current

7.4mA

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

+65°C

Series

MACX MCR-EX-T-UIREL-UP-SP

Operating Temperature Range

-20 → +65°C

Страна на произход

Germany

Детайли за продукта

MACX MCR-EX-T Series Signal Conditioners

Programmable Ex-i temperature transducer with analog output and 1 limit value relay
Standard configuration
Resistance thermometer in two, three, or four wire technology
Galvanic isolation
Wide range power supply
Spring cage connection

Warning

For a safe series connection the use of the normally open contacts at the termination points 2.5 and 2.6, as well as 3.5 and 3.6 is necessary.
For a safe parallel connection the use of the normally closed contacts of both relays at the termination points 2.4 and 2.5 respectively 3.4 and 3.5 is mandatory

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

P.O.A.

Phoenix Contact 1 Channel Galvanic Barrier, ATEX

P.O.A.

Phoenix Contact 1 Channel Galvanic Barrier, ATEX
Информацията за складовите наличности временно не е налична.

Технически документи

Спецификации

Number of Channels

1

Barrier Type

Galvanic Barrier

Maximum Voltage

125 V dc, 253V ac

Hazardous Area Certification

ATEX

Supply Voltage

24 → 230V ac/dc

Maximum Current

7.4mA

Minimum Operating Temperature

-20°C

Maximum Operating Temperature

+65°C

Series

MACX MCR-EX-T-UIREL-UP-SP

Operating Temperature Range

-20 → +65°C

Страна на произход

Germany

Детайли за продукта

MACX MCR-EX-T Series Signal Conditioners

Programmable Ex-i temperature transducer with analog output and 1 limit value relay
Standard configuration
Resistance thermometer in two, three, or four wire technology
Galvanic isolation
Wide range power supply
Spring cage connection

Warning

For a safe series connection the use of the normally open contacts at the termination points 2.5 and 2.6, as well as 3.5 and 3.6 is necessary.
For a safe parallel connection the use of the normally closed contacts of both relays at the termination points 2.4 and 2.5 respectively 3.4 and 3.5 is mandatory