Технически документи
Спецификации
Brand
MeggerTest Equipment Type
Combined Loop and RCD Tester
Product Type
Loop Impendence & RCD Combined Tester
Loop Impedance Test Type
2 Wire
Maximum Voltage Measurement
500V
RCD Test Type
AC, DC
PSC Display
Yes
RCD Test Current
1000mA
Non-Trip Loop Test
Yes
Display Type
LCD
Minimum Operating Temperature
-5°C
Loop Test Accuracy
±2 %
Battery Type
AA
Maximum Operating Temperature
40°C
Power Source
Battery
Height
203mm
Width
148 mm
Length
203mm
Weight
980g
Standards/Approvals
IEC 61326-1
Safety Category Level
CAT III
Safety Category Voltage
300V
Страна на произход
United Kingdom
Детайли за продукта
LRCD200 Loop Tester
Single-phase 3-wire non-DDR trip loop tester.
Differential circuit breaker testing 10 mA → 1000 mA.
Ramp testing to verify the DDR trip limit.
Extremely easy and safe to use.
Integrated protective front cover.
Tough rubber armoured case.
IP54 sealed.
The LRCD200 is ideal for electricians working on 230 V low-voltage networks in accordance with NFC15.100.
Auto differential circuit breaker testing (LRCD 200).
110 V loop testing, 2-wire fast testing, plus phase-phase and phase-earth measurements (LRCD220).
Информацията за складовите наличности временно не е налична.
€ 1 171,41
€ 1 171,41 Всеки (ex VAT)
1
€ 1 171,41
€ 1 171,41 Всеки (ex VAT)
Информацията за складовите наличности временно не е налична.
1
Технически документи
Спецификации
Brand
MeggerTest Equipment Type
Combined Loop and RCD Tester
Product Type
Loop Impendence & RCD Combined Tester
Loop Impedance Test Type
2 Wire
Maximum Voltage Measurement
500V
RCD Test Type
AC, DC
PSC Display
Yes
RCD Test Current
1000mA
Non-Trip Loop Test
Yes
Display Type
LCD
Minimum Operating Temperature
-5°C
Loop Test Accuracy
±2 %
Battery Type
AA
Maximum Operating Temperature
40°C
Power Source
Battery
Height
203mm
Width
148 mm
Length
203mm
Weight
980g
Standards/Approvals
IEC 61326-1
Safety Category Level
CAT III
Safety Category Voltage
300V
Страна на произход
United Kingdom
Детайли за продукта
LRCD200 Loop Tester
Single-phase 3-wire non-DDR trip loop tester.
Differential circuit breaker testing 10 mA → 1000 mA.
Ramp testing to verify the DDR trip limit.
Extremely easy and safe to use.
Integrated protective front cover.
Tough rubber armoured case.
IP54 sealed.
The LRCD200 is ideal for electricians working on 230 V low-voltage networks in accordance with NFC15.100.
Auto differential circuit breaker testing (LRCD 200).
110 V loop testing, 2-wire fast testing, plus phase-phase and phase-earth measurements (LRCD220).