Технически документи
Спецификации
Brand
FlukeAbsolute Maximum AC Current Measurement
600A ac
Absolute Maximum DC Current Measurement
200µA dc
Absolute Maximum AC Voltage Measurement
600V ac
Absolute Maximum DC Voltage Measurement
600V dc
Absolute Maximum Resistance Measurement
9.999kΩ
Model Number
902
AC Current Measurement Resolution
100mA ac
DC Current Measurement Resolution
0.1µA dc
Best DC Current Accuracy
±1% + 5 Digits
Clamp Meter Type
Continuity, Crest Factor, Current, Resistance, Temperature, Voltage
Best AC Current Accuracy
±1% +5 digits
Best AC Voltage Accuracy
±1% + 5 Digits
True RMS
Yes
Best DC Voltage Accuracy
±1% + 5 Digits
Functions Measured
AC Current, AC Voltage, Continuity, Crest Factor, DC Current, DC Voltage, Resistance, Temperature
Width
79mm
Dimensions
238 x 79 x 41mm
Best Temperature Measurement Accuracy
±1% + 0.8 °C
Minimum Operating Temperature
-10°C
Height
41mm
AC Voltage Measurement Resolution
0.1V ac
Battery Life
150 h
Weight
312g
Safety Category Level
CAT III
Safety Category Voltage
600V
Battery Type
AA
Safety Category
CAT III 600 V
Best Resistance Measurement Accuracy
±1.5% + 5 Digits
Display Type
LCD
Power Source
Battery
Length
238mm
Resistance Measurement Resolution
100mΩ
DC Voltage Measurement Resolution
0.1V dc
Maximum Conductor Size
30mm
Temperature Measurement Resolution
0.1°C
Absolute Maximum Temperature Measurement
+400°C
Maximum Operating Temperature
+50°C
Страна на произход
China
Детайли за продукта
Fluke 902 HVAC Current Clamp
600V ac/dc voltage measurement
600A ac current measurement
200μA dc current measurement ideal for flame sensor testing
Resistance and capacitance measurement
400°C contact temperature with standard K-type thermocouple
Backlit display shows actual and Min/Max measurements with display hold function
Complies with IEC 61010-1, IEC 61010-2-032 CAT III 600V
Supplied with
2 AA alkaline batteries, 1 pair TL75 test leads, 80BK integrated DMM Temperature probe, users manual, soft carrying case.
HVAC Clampmeters
Информацията за складовите наличности временно не е налична.
Моля, проверете отново по-късно.
P.O.A.
1
P.O.A.
1
Технически документи
Спецификации
Brand
FlukeAbsolute Maximum AC Current Measurement
600A ac
Absolute Maximum DC Current Measurement
200µA dc
Absolute Maximum AC Voltage Measurement
600V ac
Absolute Maximum DC Voltage Measurement
600V dc
Absolute Maximum Resistance Measurement
9.999kΩ
Model Number
902
AC Current Measurement Resolution
100mA ac
DC Current Measurement Resolution
0.1µA dc
Best DC Current Accuracy
±1% + 5 Digits
Clamp Meter Type
Continuity, Crest Factor, Current, Resistance, Temperature, Voltage
Best AC Current Accuracy
±1% +5 digits
Best AC Voltage Accuracy
±1% + 5 Digits
True RMS
Yes
Best DC Voltage Accuracy
±1% + 5 Digits
Functions Measured
AC Current, AC Voltage, Continuity, Crest Factor, DC Current, DC Voltage, Resistance, Temperature
Width
79mm
Dimensions
238 x 79 x 41mm
Best Temperature Measurement Accuracy
±1% + 0.8 °C
Minimum Operating Temperature
-10°C
Height
41mm
AC Voltage Measurement Resolution
0.1V ac
Battery Life
150 h
Weight
312g
Safety Category Level
CAT III
Safety Category Voltage
600V
Battery Type
AA
Safety Category
CAT III 600 V
Best Resistance Measurement Accuracy
±1.5% + 5 Digits
Display Type
LCD
Power Source
Battery
Length
238mm
Resistance Measurement Resolution
100mΩ
DC Voltage Measurement Resolution
0.1V dc
Maximum Conductor Size
30mm
Temperature Measurement Resolution
0.1°C
Absolute Maximum Temperature Measurement
+400°C
Maximum Operating Temperature
+50°C
Страна на произход
China
Детайли за продукта
Fluke 902 HVAC Current Clamp
600V ac/dc voltage measurement
600A ac current measurement
200μA dc current measurement ideal for flame sensor testing
Resistance and capacitance measurement
400°C contact temperature with standard K-type thermocouple
Backlit display shows actual and Min/Max measurements with display hold function
Complies with IEC 61010-1, IEC 61010-2-032 CAT III 600V
Supplied with
2 AA alkaline batteries, 1 pair TL75 test leads, 80BK integrated DMM Temperature probe, users manual, soft carrying case.