ETA Thermal Circuit Breaker / Switch - 3120 2 Pole Snap In, 16A Current Rating

Номер на артикул на RS: 286-4159Марка: ETA№ по каталога на производителя: 3120-F521-H7T1-W01D-16A
brand-logo

Технически документи

Спецификации

Brand

ETA

Current Rating

16A

Number of Poles

2

Width

25mm

Series

3120

Reset Actuator Type

Rocker

Mounting Style

Snap In

Страна на произход

Tunisia

Детайли за продукта

CBE, 2 Pole Sensing, 2 Pole Switching, 3120 Series

IEC Classification S/TO (with modules, S/TM). This range of 2 pole sensing thermal switch and circuit breaker offer enhance protection over single pole devices with the added benefit of not being 'polarity' sensitive for wiring purposes. Basic tripping time at 2xIN, 20-30 second. These units may also be used with the magnetic conversion module in this range,to convert the breaker to a thermal/magnetic type, for closer protection against short circuits. Circuit protection designed for equipment, sub-systems and components.

Depth behind panel: 43mm

Approvals

UL, CSA, VDE, BV

Thermal Magnetic Convertible

All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms).

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

P.O.A.

ETA Thermal Circuit Breaker / Switch - 3120 2 Pole Snap In, 16A Current Rating

P.O.A.

ETA Thermal Circuit Breaker / Switch - 3120 2 Pole Snap In, 16A Current Rating
Информацията за складовите наличности временно не е налична.

Технически документи

Спецификации

Brand

ETA

Current Rating

16A

Number of Poles

2

Width

25mm

Series

3120

Reset Actuator Type

Rocker

Mounting Style

Snap In

Страна на произход

Tunisia

Детайли за продукта

CBE, 2 Pole Sensing, 2 Pole Switching, 3120 Series

IEC Classification S/TO (with modules, S/TM). This range of 2 pole sensing thermal switch and circuit breaker offer enhance protection over single pole devices with the added benefit of not being 'polarity' sensitive for wiring purposes. Basic tripping time at 2xIN, 20-30 second. These units may also be used with the magnetic conversion module in this range,to convert the breaker to a thermal/magnetic type, for closer protection against short circuits. Circuit protection designed for equipment, sub-systems and components.

Depth behind panel: 43mm

Approvals

UL, CSA, VDE, BV

Thermal Magnetic Convertible

All CBEs have blade terminals and have an insulation resistance greater than 100MΩ (MegaOhms).