Entrelec, M 4/9 PV Surge Suppressor Unit 130 V dc Maximum Voltage Rating 2.5kA Maximum Surge Current Terminal Block

Номер на артикул на RS: 413-2397Марка: Entrelec№ по каталога на производителя: 1SNA007013R1300
brand-logo

Технически документи

Спецификации

Suppressor Type

Terminal Block with Transient Voltage Suppressor

Maximum Voltage Rating

130 V dc

Mounting Type

DIN Rail

Maximum Surge Current

2.5kA

Series

M 4/9 PV

Length

65.5mm

Depth

64.5mm

Minimum Operating Temperature

-55°C

Maximum Operating Temperature

+130°C

Детайли за продукта

Surge Protected Terminal Block

Grey nylon polyamide 6.6 moulding
Captive terminal screws with hardened heads
Compact 9mm spacing size
Deep Top Hat or G type rail mounting
Location category Zone 2
Dimensions 65.5 x 67mm

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

€ 10,13

€ 10,13 Всеки (ex VAT)

Entrelec, M 4/9 PV Surge Suppressor Unit 130 V dc Maximum Voltage Rating 2.5kA Maximum Surge Current Terminal Block

€ 10,13

€ 10,13 Всеки (ex VAT)

Entrelec, M 4/9 PV Surge Suppressor Unit 130 V dc Maximum Voltage Rating 2.5kA Maximum Surge Current Terminal Block

Информацията за складовите наличности временно не е налична.

Информацията за складовите наличности временно не е налична.

Технически документи

Спецификации

Suppressor Type

Terminal Block with Transient Voltage Suppressor

Maximum Voltage Rating

130 V dc

Mounting Type

DIN Rail

Maximum Surge Current

2.5kA

Series

M 4/9 PV

Length

65.5mm

Depth

64.5mm

Minimum Operating Temperature

-55°C

Maximum Operating Temperature

+130°C

Детайли за продукта

Surge Protected Terminal Block

Grey nylon polyamide 6.6 moulding
Captive terminal screws with hardened heads
Compact 9mm spacing size
Deep Top Hat or G type rail mounting
Location category Zone 2
Dimensions 65.5 x 67mm

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.