Suppressor Type

Surge Arrester Protection Module

Packaging

1 pieces

Страна на произход

Germany

Детайли за продукта

DEHNguard and DEHNrail Replacement Plugin Modules

Spare plugs for Modular Surge Arresters
Energy coordinated with other arresters of the Dehn Redline family
Operating status and fault indictor window
High reliability due to Thermo Dynamic Control monitoring
No tool to replace modules in service

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Информацията за складовите наличности временно не е налична.

€ 123,62

€ 123,62 Всеки (ex VAT)

Dehn Surge Arrester Protection Module

€ 123,62

€ 123,62 Всеки (ex VAT)

Dehn Surge Arrester Protection Module

Информацията за складовите наличности временно не е налична.

количествоЕдинична цена
1 - 4€ 123,62
5 - 9€ 118,67
10 - 24€ 112,50
25+€ 102,61

Технически документи

Спецификации

Brand

Dehn

Suppressor Type

Surge Arrester Protection Module

Packaging

1 pieces

Страна на произход

Germany

Детайли за продукта

DEHNguard and DEHNrail Replacement Plugin Modules

Spare plugs for Modular Surge Arresters
Energy coordinated with other arresters of the Dehn Redline family
Operating status and fault indictor window
High reliability due to Thermo Dynamic Control monitoring
No tool to replace modules in service

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.