Crouzet 81 series 8 bar Pneumatic Memory Module with Memory Element function

Номер на артикул на RS: 655-6852Марка: Crouzet№ по каталога на производителя: 81523205
brand-logo

Технически документи

Спецификации

Brand

Crouzet

Product Type

Pneumatic Memory Module

Logic Function

Memory Element

Series

81

Minimum Operating Pressure

2bar

Hazardous Area Certification

ATEX

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-5°C

Maximum Operating Temperature

50°C

Width

9 mm

Standards/Approvals

Directive 94/9/EC

Connection Type

On Sub-Base

Страна на произход

France

Детайли за продукта

Memory relay with pressure indicator

Operating principle: The appearance of the "X1" pressure signal causes the valve to move. The "x" output is pressurised. This status is stored in memory until the "X0" pressure signal is received. This pressure
signal causes the valve to move in the reverse direction. The "x" output is pressurised. This status is also saved in memory.
- the "x" pressure output indicates that the information saved in memory is "X1",
- the "x" pressure output indicates that the information saved in memory is "X0".

Информацията за складовите наличности временно не е налична.

€ 206,66

€ 206,66 Всеки (ex VAT)

Crouzet 81 series 8 bar Pneumatic Memory Module with Memory Element function

€ 206,66

€ 206,66 Всеки (ex VAT)

Crouzet 81 series 8 bar Pneumatic Memory Module with Memory Element function

Информацията за складовите наличности временно не е налична.

количествоЕдинична цена
1 - 4€ 206,66
5 - 9€ 200,92
10 - 24€ 195,49
25 - 49€ 190,33
50+€ 185,46

Технически документи

Спецификации

Brand

Crouzet

Product Type

Pneumatic Memory Module

Logic Function

Memory Element

Series

81

Minimum Operating Pressure

2bar

Hazardous Area Certification

ATEX

Maximum Operating Pressure

8 bar

Minimum Operating Temperature

-5°C

Maximum Operating Temperature

50°C

Width

9 mm

Standards/Approvals

Directive 94/9/EC

Connection Type

On Sub-Base

Страна на произход

France

Детайли за продукта

Memory relay with pressure indicator

Operating principle: The appearance of the "X1" pressure signal causes the valve to move. The "x" output is pressurised. This status is stored in memory until the "X0" pressure signal is received. This pressure
signal causes the valve to move in the reverse direction. The "x" output is pressurised. This status is also saved in memory.
- the "x" pressure output indicates that the information saved in memory is "X1",