Absolute Maximum Current Measurement

6500 A ac, 1700 A dcA

Absolute Maximum Power Measurement

9999 kW, 9999 kVar, 9999kVA

Number of Phases

1, 3

Maximum Voltage

600V ac

Best Voltage Measurement Accuracy

±0.5% +2 Digits

Best Current Measurement Accuracy

±0,5% +1 Digit

Display Type

Backlit LCD

Measurement Type

Current, Energy, Frequency, Harmonics, Inrush Current, Phase rotation, Power, Resistance (winding), RPM, Temperature, Voltage

Measurement Standards

IEC62301

Interface Type

RS232, USB

Power Source

Battery, Mains

Battery Type

AA

Model Number p

CA 8220

Battery Life

20h

Model Number (p)

CA 8220

Weight

880g

Maximum Operating Temperature

+50°C

Width

108mm

Length

211mm

Maximum Frequency

69Hz

Minimum Frequency

40 Hz

Dimensions

211 x 108 x 60mm

Minimum Operating Temperature

0°C

Height

60mm

Страна на произход

France

Детайли за продукта

C.A 8220 and C.A 8230 Power Analysers

Single-phase or balanced three-phase power analyser designed for tradesmen and installers in the public or private construction industry and in maintenance departments.
This economical and easy-to-use analyser is suitable for testing electrical installations, especially those with systems which use power electronics.
The broad range of measurements it provides (VA, VAR, W, PF…) makes this instrument ideal for technical or technological teaching.
Its large graphic display (320 x 240 pixels) serves as a demonstration tool (CA8230 model).
The instrument is easy and pleasant to handle and intuitive to use.
For enhanced simplicity and safety, it automatically recognises the type of sensor connected.
Software PAT (Power Analyser Transfer) greatly increases the instrument's potential in terms of its configuration, and recovery and processing of data on a PC.
Current probes are available as accessories: Ampflex A193 and MN93A.

C.A 8220

V Max: 600 VRMS.
I (max) Arms to 3000 A.
Power: 1.2 W → 10 MW - VA, var, PF / Cos / Tan.
Accuracy: 0.5%.
Harmonics: THD, 1 to 50th order rk rms and %.
Values: Min, Max, Peak.
Phase rotation.
Speed of rotation.
Energy measurement.
Temperature (PT100).
Memory: 99 pages max.
Bandwidth: 40 → 70 Hz.
Sampling frequency: 12.8 kHz.
B&W display.

C.A 8230 (P01160630B)

V Max: 600 VRMS.
I (max) Arms to 3000 A.
Power: 1.2 W → 3.4 W - VA, var, PF / Cos / Tan.
Accuracy: 0.5%.
Harmonics: THD, 1 to 50th order rk rms and %, DF.
Values: Min, Max, Peak.
Functions: Threshold monitoring.
Records up to several days.
Event capture.
Energy measurement.
Engine start-up display.
Memory: 1.5 MB.
Bandwidth: 40 → 70 Hz.
Sampling frequency: 12.8 kHz.
Colour display.

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

€ 925,87

Всеки (ex VAT)

Chauvin Arnoux CA 8220 Power Quality Analyser, 1, 3-Phase, 6500A Max, 600V ac Max

€ 925,87

Всеки (ex VAT)

Chauvin Arnoux CA 8220 Power Quality Analyser, 1, 3-Phase, 6500A Max, 600V ac Max
Информацията за складовите наличности временно не е налична.

Технически документи

Спецификации

Absolute Maximum Current Measurement

6500 A ac, 1700 A dcA

Absolute Maximum Power Measurement

9999 kW, 9999 kVar, 9999kVA

Number of Phases

1, 3

Maximum Voltage

600V ac

Best Voltage Measurement Accuracy

±0.5% +2 Digits

Best Current Measurement Accuracy

±0,5% +1 Digit

Display Type

Backlit LCD

Measurement Type

Current, Energy, Frequency, Harmonics, Inrush Current, Phase rotation, Power, Resistance (winding), RPM, Temperature, Voltage

Measurement Standards

IEC62301

Interface Type

RS232, USB

Power Source

Battery, Mains

Battery Type

AA

Model Number p

CA 8220

Battery Life

20h

Model Number (p)

CA 8220

Weight

880g

Maximum Operating Temperature

+50°C

Width

108mm

Length

211mm

Maximum Frequency

69Hz

Minimum Frequency

40 Hz

Dimensions

211 x 108 x 60mm

Minimum Operating Temperature

0°C

Height

60mm

Страна на произход

France

Детайли за продукта

C.A 8220 and C.A 8230 Power Analysers

Single-phase or balanced three-phase power analyser designed for tradesmen and installers in the public or private construction industry and in maintenance departments.
This economical and easy-to-use analyser is suitable for testing electrical installations, especially those with systems which use power electronics.
The broad range of measurements it provides (VA, VAR, W, PF…) makes this instrument ideal for technical or technological teaching.
Its large graphic display (320 x 240 pixels) serves as a demonstration tool (CA8230 model).
The instrument is easy and pleasant to handle and intuitive to use.
For enhanced simplicity and safety, it automatically recognises the type of sensor connected.
Software PAT (Power Analyser Transfer) greatly increases the instrument's potential in terms of its configuration, and recovery and processing of data on a PC.
Current probes are available as accessories: Ampflex A193 and MN93A.

C.A 8220

V Max: 600 VRMS.
I (max) Arms to 3000 A.
Power: 1.2 W → 10 MW - VA, var, PF / Cos / Tan.
Accuracy: 0.5%.
Harmonics: THD, 1 to 50th order rk rms and %.
Values: Min, Max, Peak.
Phase rotation.
Speed of rotation.
Energy measurement.
Temperature (PT100).
Memory: 99 pages max.
Bandwidth: 40 → 70 Hz.
Sampling frequency: 12.8 kHz.
B&W display.

C.A 8230 (P01160630B)

V Max: 600 VRMS.
I (max) Arms to 3000 A.
Power: 1.2 W → 3.4 W - VA, var, PF / Cos / Tan.
Accuracy: 0.5%.
Harmonics: THD, 1 to 50th order rk rms and %, DF.
Values: Min, Max, Peak.
Functions: Threshold monitoring.
Records up to several days.
Event capture.
Energy measurement.
Engine start-up display.
Memory: 1.5 MB.
Bandwidth: 40 → 70 Hz.
Sampling frequency: 12.8 kHz.
Colour display.