Технически документи
Спецификации
Brand
Chauvin ArnouxAdapter Type
AC
Product Type
Current Clamp
Maximum AC Current
200A ac
Accuracy
±1 %
Maximum Conductor Size
20mm
Cable Length
1.5m
Output Type
Current
Connector Type
4 mm Safety Plug
Battery Type
Alkaline, AA, LR6
Minimum Operating Temperature
-10°C
Maximum Operating Temperature
55°C
Standards/Approvals
No
Safety Category Level
Aurix
Safety Category Voltage
600V
Страна на произход
France
Детайли за продукта
MN73 Current clamp for AC current
The current clamp has a wide measurement range (up to 200 A). The MN73 current clamp can also measure very low currents.
Current calibres: 0.01 A AC to 2.4 A AC and 0.1 A AC to 200 A AC
Bandwidth:40 Hz to 10 kHz
Operating voltage: 600 V rms
Max. jaw opening: 20 mm
Output: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4 mm)
Electrical safety: IEC 1010-1 and IEC 1010-2-032
600 V category III, pollution degree 2
300 V category IV, pollution degree 2
Supplied with
Operating manual.
Информацията за складовите наличности временно не е налична.
€ 380,12
€ 380,12 Всеки (ex VAT)
1
€ 380,12
€ 380,12 Всеки (ex VAT)
Информацията за складовите наличности временно не е налична.
1
Технически документи
Спецификации
Brand
Chauvin ArnouxAdapter Type
AC
Product Type
Current Clamp
Maximum AC Current
200A ac
Accuracy
±1 %
Maximum Conductor Size
20mm
Cable Length
1.5m
Output Type
Current
Connector Type
4 mm Safety Plug
Battery Type
Alkaline, AA, LR6
Minimum Operating Temperature
-10°C
Maximum Operating Temperature
55°C
Standards/Approvals
No
Safety Category Level
Aurix
Safety Category Voltage
600V
Страна на произход
France
Детайли за продукта
MN73 Current clamp for AC current
The current clamp has a wide measurement range (up to 200 A). The MN73 current clamp can also measure very low currents.
Current calibres: 0.01 A AC to 2.4 A AC and 0.1 A AC to 200 A AC
Bandwidth:40 Hz to 10 kHz
Operating voltage: 600 V rms
Max. jaw opening: 20 mm
Output: 1.5 m two-wire lead with double or reinforced insulation terminated by 2 elbowed male safety plugs (4 mm)
Electrical safety: IEC 1010-1 and IEC 1010-2-032
600 V category III, pollution degree 2
300 V category IV, pollution degree 2
Supplied with
Operating manual.