Технически документи
Спецификации
Brand
Chauvin ArnouxAdapter Type
AC
Maximum ac Current
400A ac
Best Accuracy
≤ 0.35 %
Maximum Conductor Size
115mm
Safety Category
CAT III 600 V, CAT IV 300V
Output Type
Current
Connector Type
4 mm Plug
Cable Length Extended
1.5m
Cable Length (Extended)
1.5m
Maximum Operating Temperature
+55°C
Model Number p
B102
Model Number (p)
B102
Minimum Operating Temperature
-10°C
Safety Category Level
CAT III, CAT IV
Safety Category Voltage
300 V, 600V
Страна на произход
France
Детайли за продукта
B102 Leakage Current Clamp
The B102 current clamp is designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. The current clamp is specially designed to detect low fault currents on power circuits.
The measurements can be made on any type of installation: single-phase, 3 or 4 wire threephase, balanced or not, with the neutral grounded earth or impedant
Differential or leakage current, from 500 μA
Current up to 400 A max
2 measurement ranges: 4 A AC / 400 A AC
Bandwidth: 48 Hz to 1000 Hz
Output: 1.5 m cord with double insulation having male safety plugs 4mm in diameter
€ 1 213,34
€ 1 213,34 Всеки (ex VAT)
1
€ 1 213,34
€ 1 213,34 Всеки (ex VAT)
1
Информацията за складовите наличности временно не е налична.
Моля, проверете отново по-късно.
Технически документи
Спецификации
Brand
Chauvin ArnouxAdapter Type
AC
Maximum ac Current
400A ac
Best Accuracy
≤ 0.35 %
Maximum Conductor Size
115mm
Safety Category
CAT III 600 V, CAT IV 300V
Output Type
Current
Connector Type
4 mm Plug
Cable Length Extended
1.5m
Cable Length (Extended)
1.5m
Maximum Operating Temperature
+55°C
Model Number p
B102
Model Number (p)
B102
Minimum Operating Temperature
-10°C
Safety Category Level
CAT III, CAT IV
Safety Category Voltage
300 V, 600V
Страна на произход
France
Детайли за продукта
B102 Leakage Current Clamp
The B102 current clamp is designed for measuring leakage current diverted towards the earth. It enables the fault to be located or anticipated without disconnecting the equipment linked. The current clamp is specially designed to detect low fault currents on power circuits.
The measurements can be made on any type of installation: single-phase, 3 or 4 wire threephase, balanced or not, with the neutral grounded earth or impedant
Differential or leakage current, from 500 μA
Current up to 400 A max
2 measurement ranges: 4 A AC / 400 A AC
Bandwidth: 48 Hz to 1000 Hz
Output: 1.5 m cord with double insulation having male safety plugs 4mm in diameter