Carlo Gavazzi Voltage Monitoring Relay, SPDT, 8 → 28V dc, DIN Rail
Технически документи
Спецификации
Brand
Carlo GavazziMonitoring Application
Voltage
Contact Configuration
SPDT
Voltage Sensing Range
8 → 28V dc
Voltage Sensitivity
Undervoltage
Mounting Type
DIN Rail
Time Delay
<200ms
Series
DUA52
Terminal Type
Screw
Minimum Operating Temperature
-20°C
Width
17.5mm
Maximum Operating Temperature
+60°C
Dimensions
67.2 x 17.5 x 81mm
Maximum Voltage Sensed
28V dc
Height
81mm
Length
67.2mm
Minimum Voltage Sensed
8V dc
Operating Temperature Range
+60°C
Страна на произход
China
Детайли за продукта
DUA52 DC Under Voltage Relays
Carlo Gavazzi DUA52 series DC under voltage monitoring relay that measure its own power supply. The DUA52 can monitor two separate measuring ranges of 8-28 V dc and 38- 58 V dc. It has separate potentiometers for set point and hysteresis. Typical applications are monitoring of backup batteries and batteries on diesel generator sets.
DC under voltage monitoring relay
Measures its own power supply
Measuring ranges: 8 - 28 V dc and 38 - 58 V dc
Adjustable hysteresis: 4 to 50%
DIN-rail mounting
LED indication for relay and power supply
Информацията за складовите наличности временно не е налична.
Моля, проверете отново по-късно.
€ 90,91
Всеки (ex VAT)
1
€ 90,91
Всеки (ex VAT)
1
Купете в насипно състояние
количество | Единична цена |
---|---|
1 - 4 | € 90,91 |
5+ | € 87,21 |
Технически документи
Спецификации
Brand
Carlo GavazziMonitoring Application
Voltage
Contact Configuration
SPDT
Voltage Sensing Range
8 → 28V dc
Voltage Sensitivity
Undervoltage
Mounting Type
DIN Rail
Time Delay
<200ms
Series
DUA52
Terminal Type
Screw
Minimum Operating Temperature
-20°C
Width
17.5mm
Maximum Operating Temperature
+60°C
Dimensions
67.2 x 17.5 x 81mm
Maximum Voltage Sensed
28V dc
Height
81mm
Length
67.2mm
Minimum Voltage Sensed
8V dc
Operating Temperature Range
+60°C
Страна на произход
China
Детайли за продукта
DUA52 DC Under Voltage Relays
Carlo Gavazzi DUA52 series DC under voltage monitoring relay that measure its own power supply. The DUA52 can monitor two separate measuring ranges of 8-28 V dc and 38- 58 V dc. It has separate potentiometers for set point and hysteresis. Typical applications are monitoring of backup batteries and batteries on diesel generator sets.
DC under voltage monitoring relay
Measures its own power supply
Measuring ranges: 8 - 28 V dc and 38 - 58 V dc
Adjustable hysteresis: 4 to 50%
DIN-rail mounting
LED indication for relay and power supply