Bourns, 1250 Surge Arrester 600 V ac Maximum Voltage Rating 50kA Maximum Surge Current 3 Pole Protector

Номер на артикул на RS: 172-9928Марка: Bourns№ по каталога на производителя: 1250-3S-400
brand-logo

Технически документи

Спецификации

Brand

Bourns

Suppressor Type

3 Pole Protector

Maximum Voltage Rating

600 V ac

Mounting Type

DIN Rail

Maximum Surge Current

50kA

Series

1250

Length

54mm

Depth

67mm

Height

90mm

Dimensions

54 x 67 x 90mm

Minimum Operating Temperature

-50°C

Maximum Operating Temperature

+85°C

Страна на произход

China

Детайли за продукта

Bourns 1250 series Surge Protection Devices

50 kA max. discharge current rating
Multi-pole uni-block design
DIN Rail mountable
UL 60691 compliant integrated thermal disconnect
Visual fault indicator
Remote signalling capability
Compact design ideal for limited spaces

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

€ 292,901

Each (In a Box of 3) (ex VAT)

Bourns, 1250 Surge Arrester 600 V ac Maximum Voltage Rating 50kA Maximum Surge Current 3 Pole Protector

€ 292,901

Each (In a Box of 3) (ex VAT)

Bourns, 1250 Surge Arrester 600 V ac Maximum Voltage Rating 50kA Maximum Surge Current 3 Pole Protector
Информацията за складовите наличности временно не е налична.

Технически документи

Спецификации

Brand

Bourns

Suppressor Type

3 Pole Protector

Maximum Voltage Rating

600 V ac

Mounting Type

DIN Rail

Maximum Surge Current

50kA

Series

1250

Length

54mm

Depth

67mm

Height

90mm

Dimensions

54 x 67 x 90mm

Minimum Operating Temperature

-50°C

Maximum Operating Temperature

+85°C

Страна на произход

China

Детайли за продукта

Bourns 1250 series Surge Protection Devices

50 kA max. discharge current rating
Multi-pole uni-block design
DIN Rail mountable
UL 60691 compliant integrated thermal disconnect
Visual fault indicator
Remote signalling capability
Compact design ideal for limited spaces

Surge Protection Devices, SPDs (DIN-rail)

Voltage surges, often referred to as spikes or transients are typically caused by switching of fluorescent lights, fuses blowing or nearby lightning activity. The worst voltage spikes are usually caused by lightning strikes and can reach up to 6000V, with current surges of over 3000A. The maximum size of the let-through voltage and current inrush depends on the location within the building's wiring system. BS7671: 2011 Amendment 1 Sections 443 and 534 cover risk assessment and provides guidance on protection of electronic equipment for installation engineers to follow. The fullest information on lightning and surge protection comes from the BSEN 62305 series of standards.