Технически документи
Спецификации
Automotive Standard
AEC-Q200
Minimum Operating Temperature
-55°C
Power Rating
0.1W
Maximum Operating Temperature
+155°C
Technology
Thick Film
Tolerance
±1%
Temperature Coefficient
±100ppm/°C
Resistance
2.2kΩ
Package/Case
0402 (1005M)
Series
ERJ2RK
Brand
PanasonicСтрана на произход
China
Детайли за продукта
ULYS MD80 Energy Meter
The ULYS MD80 is an energy meter designed for energy management applications and is usable locally or remotely via its pulse outputs. The meter is used for 230 V ac single phase networks and is compact in size and easy to install.
Features and Benefits
2 DIN modules, compact size
LCD backlit display
Direct current input up to 80 A
Multiple measurements; U, V, I, PF, F
Tariff-change input (double tariff)
2 Pulse outputs configurable as P, Q or S
Connection error indicator
Customisation of the display to fit the user profile
Communication via the ULYSCOM communication modules (Ethernet, RS485 M-bus, KNX)
Automatic recognition of the associated communication module via an infrared link on side of meter
Lead-sealable terminal covers
MID certification option available (124-2445 only)
Accuracy class 1 as per EN IEC 62053-21
Информацията за складовите наличности временно не е налична.
Моля, проверете отново по-късно.
€ 0,002
Each (On a Reel of 10000) (ex VAT)
10000
€ 0,002
Each (On a Reel of 10000) (ex VAT)
10000
Технически документи
Спецификации
Automotive Standard
AEC-Q200
Minimum Operating Temperature
-55°C
Power Rating
0.1W
Maximum Operating Temperature
+155°C
Technology
Thick Film
Tolerance
±1%
Temperature Coefficient
±100ppm/°C
Resistance
2.2kΩ
Package/Case
0402 (1005M)
Series
ERJ2RK
Brand
PanasonicСтрана на произход
China
Детайли за продукта
ULYS MD80 Energy Meter
The ULYS MD80 is an energy meter designed for energy management applications and is usable locally or remotely via its pulse outputs. The meter is used for 230 V ac single phase networks and is compact in size and easy to install.
Features and Benefits
2 DIN modules, compact size
LCD backlit display
Direct current input up to 80 A
Multiple measurements; U, V, I, PF, F
Tariff-change input (double tariff)
2 Pulse outputs configurable as P, Q or S
Connection error indicator
Customisation of the display to fit the user profile
Communication via the ULYSCOM communication modules (Ethernet, RS485 M-bus, KNX)
Automatic recognition of the associated communication module via an infrared link on side of meter
Lead-sealable terminal covers
MID certification option available (124-2445 only)
Accuracy class 1 as per EN IEC 62053-21