Teledyne LeCroy DXC200 Oscilloscope Probe, Passive Type, 50MHz, 1:1

Номер на артикул на RS: 801-4886Марка: Teledyne LeCroy№ по каталога на производителя: DXC200
brand-logo

Технически документи

Спецификации

Probe Type

Passive

Attenuation

1:1

Bandwidth

50MHz

Maximum Common Mode Input Voltage

500V

Model Number p

DXC200

Number of Probes

2

Rise Time

7 ns, 35ns

Страна на произход

United States

Детайли за продукта

Teledyne LeCroy Low Capacitance Passive Differential Probe Pair DXC200

The DXC200 is a pair of x1 probes matched for differential measurement applications. The DXC200 is designed to minimise capacitance loading (compared to coaxial cable) while still maintaining practical probe-to-circuit attachment. Full DA1800 series amplifier gain and Common Mode Rejection Ratio (CMRR) are maintained. The full gain capability of the DA1800 Series is available at the probe tip. The DXC200 allows the user to take advantage of the DA1800 series's 100MΩ input resistance setting.

DC to 50MHz with DA1855A ( 801-4852 )
Maximum input voltage 500V (limited to amplifier maximum input voltage)
x1 differential probe pair
0.7m cable length

Passive Oscilloscope Probes

Може да се интересувате от
Информацията за складовите наличности временно не е налична.

P.O.A.

Teledyne LeCroy DXC200 Oscilloscope Probe, Passive Type, 50MHz, 1:1

P.O.A.

Teledyne LeCroy DXC200 Oscilloscope Probe, Passive Type, 50MHz, 1:1
Информацията за складовите наличности временно не е налична.

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Може да се интересувате от

Технически документи

Спецификации

Probe Type

Passive

Attenuation

1:1

Bandwidth

50MHz

Maximum Common Mode Input Voltage

500V

Model Number p

DXC200

Number of Probes

2

Rise Time

7 ns, 35ns

Страна на произход

United States

Детайли за продукта

Teledyne LeCroy Low Capacitance Passive Differential Probe Pair DXC200

The DXC200 is a pair of x1 probes matched for differential measurement applications. The DXC200 is designed to minimise capacitance loading (compared to coaxial cable) while still maintaining practical probe-to-circuit attachment. Full DA1800 series amplifier gain and Common Mode Rejection Ratio (CMRR) are maintained. The full gain capability of the DA1800 Series is available at the probe tip. The DXC200 allows the user to take advantage of the DA1800 series's 100MΩ input resistance setting.

DC to 50MHz with DA1855A ( 801-4852 )
Maximum input voltage 500V (limited to amplifier maximum input voltage)
x1 differential probe pair
0.7m cable length

Passive Oscilloscope Probes