Brand

ELC

Output Voltage

12/24V dc

Input Voltage

230V ac

Mounting Type

DIN Rail Mount

Width

54mm

Depth

95mm

Minimum Temperature

+5°C

Output Voltage Adjustment Range

10 → 14 V, 20 → 28 V

Maximum Temperature

+40°C

Страна на произход

France

Детайли за продукта

Back-up module

Designed to supply up to 10 A and lead batteries from 2 → 20 Ah.
Can be used directly on 12 or 24 V systems.
Automatic configuration to 12 or 24 V.
G.T.C: Reports faults on relay status.
Mains power supply interruptions are detected by opto-coupler and automatic switching without cut-off.
Device for monitoring battery status and load current.
Adjustable load current from 0.3 → 2 A.
Push-button release for "bypass" systems
Protection against overcurrents and short circuits via a 10 A fuse.
Spring and lever terminals.
Modular, for clipping onto DIN rail and wall mount.

Approvals

EMC EN 61000-6-2 and EN 61000-6-4

Standards

NF S 61-940 class II

Информацията за складовите наличности временно не е налична.

€ 80,26

€ 80,26 Всеки (ex VAT)

ELC 230V ac Input DIN Rail Mount Backup Module

€ 80,26

€ 80,26 Всеки (ex VAT)

ELC 230V ac Input DIN Rail Mount Backup Module
Информацията за складовите наличности временно не е налична.

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Технически документи

Спецификации

Brand

ELC

Output Voltage

12/24V dc

Input Voltage

230V ac

Mounting Type

DIN Rail Mount

Width

54mm

Depth

95mm

Minimum Temperature

+5°C

Output Voltage Adjustment Range

10 → 14 V, 20 → 28 V

Maximum Temperature

+40°C

Страна на произход

France

Детайли за продукта

Back-up module

Designed to supply up to 10 A and lead batteries from 2 → 20 Ah.
Can be used directly on 12 or 24 V systems.
Automatic configuration to 12 or 24 V.
G.T.C: Reports faults on relay status.
Mains power supply interruptions are detected by opto-coupler and automatic switching without cut-off.
Device for monitoring battery status and load current.
Adjustable load current from 0.3 → 2 A.
Push-button release for "bypass" systems
Protection against overcurrents and short circuits via a 10 A fuse.
Spring and lever terminals.
Modular, for clipping onto DIN rail and wall mount.

Approvals

EMC EN 61000-6-2 and EN 61000-6-4

Standards

NF S 61-940 class II