Time ElectronicAbsolute Maximum Voltage Measurement
10V
Calibrated
RSCAL
Absolute Maximum Current Measurement
30mA
Best Accuracy
±0.02 %
Output Voltage Noise
10ppm
Power Source
Mains
Dimensions
193 x 217 x 160mm
Weight
3.3kg
Height
160mm
Length
193mm
Maximum Source Current
30mA
Width
217mm
Minimum Source Current
0mA
Model Number p
1010
Maximum Source Voltage
10V
Plug Type
Type G - British 3-pin
Minimum Source Voltage
0.01µV
Model Number (p)
1010
Страна на произход
United Kingdom
Детайли за продукта
DC Millivolt Calibrator 1010
Solid state battery/mains powered instrument suitable for applications requiring a precision voltage source of low internal resistance. The 1010 has five ranges up to 10V with a resolution up to 0.01uV. Its small size, robust construction and independence of mains power make it easily portable and convenient for laboratory, field and industrial use. Carry case 816-0191 is available separately for use with Time Electronic 1010 DC voltage calibrator and with Time Electronic 1024 DC current calibrator.
0.01uV to 10V
0.02% accuracy
Battery / mains operation
30mA output current
10 ppm/hr stability
Front panel battery level indicator
Supplied with
internal rechargeable battery
Информацията за складовите наличности временно не е налична.
Моля, проверете отново по-късно.
P.O.A.
1
P.O.A.
1
Технически документи
Спецификации
Brand
Time ElectronicAbsolute Maximum Voltage Measurement
10V
Calibrated
RSCAL
Absolute Maximum Current Measurement
30mA
Best Accuracy
±0.02 %
Output Voltage Noise
10ppm
Power Source
Mains
Dimensions
193 x 217 x 160mm
Weight
3.3kg
Height
160mm
Length
193mm
Maximum Source Current
30mA
Width
217mm
Minimum Source Current
0mA
Model Number p
1010
Maximum Source Voltage
10V
Plug Type
Type G - British 3-pin
Minimum Source Voltage
0.01µV
Model Number (p)
1010
Страна на произход
United Kingdom
Детайли за продукта
DC Millivolt Calibrator 1010
Solid state battery/mains powered instrument suitable for applications requiring a precision voltage source of low internal resistance. The 1010 has five ranges up to 10V with a resolution up to 0.01uV. Its small size, robust construction and independence of mains power make it easily portable and convenient for laboratory, field and industrial use. Carry case 816-0191 is available separately for use with Time Electronic 1010 DC voltage calibrator and with Time Electronic 1024 DC current calibrator.
0.01uV to 10V
0.02% accuracy
Battery / mains operation
30mA output current
10 ppm/hr stability
Front panel battery level indicator
Supplied with