Вземете 7 % отстъпка за всички онлайн поръчки след регистрация с RS.

регистрирайте се сега

RS PRO Type N Thermocouple 1m Length, 2mm Diameter → +250°C

Номер на артикул на RS: 621-2136Марка: RS PRO
brand-logo
Преглед на всички в Термодвойки

Технически документи

Спецификации

Brand

RS Pro

Thermocouple Type

N

Probe Diameter

2mm

Probe Length

1m

Probe Material

Teflon PTFE

Maximum Temperature Sensed

+250°C

Termination Type

Cable

Cable Length

1m

Standards Met

RoHS Compliant

Response Time

0.5 s

Страна на произход

France

Детайли за продукта

RS Pro IEC PTFE Grounded Welded Tip Wire Thermocoupless

From RS Pro a range of Type J, K, N and T wire type thermocouple temperature sensors that conform to IEC 60584. These thermocouples have a welded grounded junction for a fast response time and leads with a durable PTFE insulation

How does a Thermocouple Work?

A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

Welded Grounded Junction

In a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.

Key Features and Benefits

• Welded grounded junction with fast response
• Conform to IEC 60584 standards
• PTFE insulated leads for for resistance to oils, acid, fluids and good mechanical strength and flexibility

Applications

These grounded junction Type J, K, N and T wire thermocouples are Ideal for test and development applications including test and measurement, temperature mapping and OEM applications

Standards

IEC-BS 4937 60584-2 & IEC-BS 4937 60584-3

Може да се интересувате от
Type N Thermocouple → +1200°C
P.O.A.Each (In a Pack of 5) (ex VAT)

Информацията за складовите наличности временно не е налична.

Моля, проверете отново по-късно.

Информацията за складовите наличности временно не е налична.

€ 30,215

Each (In a Pack of 5) (ex VAT)

RS PRO Type N Thermocouple 1m Length, 2mm Diameter → +250°C

€ 30,215

Each (In a Pack of 5) (ex VAT)

RS PRO Type N Thermocouple 1m Length, 2mm Diameter → +250°C
Информацията за складовите наличности временно не е налична.

Купете в насипно състояние

количествоЕдинична ценаPer Опаковка
5 - 20€ 30,215€ 151,08
25 - 45€ 28,706€ 143,53
50+€ 27,194€ 135,97
Може да се интересувате от
Type N Thermocouple → +1200°C
P.O.A.Each (In a Pack of 5) (ex VAT)

Технически документи

Спецификации

Brand

RS Pro

Thermocouple Type

N

Probe Diameter

2mm

Probe Length

1m

Probe Material

Teflon PTFE

Maximum Temperature Sensed

+250°C

Termination Type

Cable

Cable Length

1m

Standards Met

RoHS Compliant

Response Time

0.5 s

Страна на произход

France

Детайли за продукта

RS Pro IEC PTFE Grounded Welded Tip Wire Thermocoupless

From RS Pro a range of Type J, K, N and T wire type thermocouple temperature sensors that conform to IEC 60584. These thermocouples have a welded grounded junction for a fast response time and leads with a durable PTFE insulation

How does a Thermocouple Work?

A thermocouple is a sensor used to measure temperature in a range of different processes and consists of two wire legs made from different metals joined together at their two ends to form two junctions. The hot, or measuring junction is connected to the body whose temperature is going to be measured. The cold junction or reference junction is connected to a body of known temperature. When the measuring junction is placed on something hot a voltage or potential difference between this and the reference junction occurs. This voltage can then be converted into a temperature measurement using thermocouple reference tables. This process is also known as the Seebeck Effect

Welded Grounded Junction

In a welded grounded junction the two thermocouple wires and sheath are welded together to form one junction at the probe tip. These thermocouples have a fast response time because all the thermocouple is making contact with the sheath allowing the heat to transfer easily.

Key Features and Benefits

• Welded grounded junction with fast response
• Conform to IEC 60584 standards
• PTFE insulated leads for for resistance to oils, acid, fluids and good mechanical strength and flexibility

Applications

These grounded junction Type J, K, N and T wire thermocouples are Ideal for test and development applications including test and measurement, temperature mapping and OEM applications

Standards

IEC-BS 4937 60584-2 & IEC-BS 4937 60584-3

Може да се интересувате от
Type N Thermocouple → +1200°C
P.O.A.Each (In a Pack of 5) (ex VAT)