Технически документи
Спецификации
Brand
Phoenix ContactModule Type
Current Transducer
Input Signal Type
Current
Output Signal Type
Current
Input Range
5A
Output Range
0 → 20mA
Mounting Type
Chassis Mount
Operating Temperature Range
-25 → +60°C
Series
MCR-SLP
Minimum Operating Temperature
-25°C
Maximum Operating Temperature
+60°C
Страна на произход
Germany
Детайли за продукта
MCR-SLP-1-5-UI-0 Current transducer - 2814359
The 2814359 from Phoenix Contact is an MCR passive current measuring transducer used for sinusoidal alternating currents. This transducer can convert AC into analogue signals ranging from 1-20mA or 0-10 V. The module is powered purely through the loop, so no need for any external power. With being loop-powered, this device also mounts on a DIN rail, making it a great addition to your cabinet, making it effortless to convert into analogue signals. Not to mention, 2814359 also has great accuracy with its transmission error only at 0.5%.
Features and benefits:
- Passive currently transformers without any auxiliary power
- Screw connection method accepting wire sizes from 0.2 up to 2.5 mm2
- Limit monitor
- Limit value and alarm suppression time set by two potentiometers
- DIN rail - width of only 22.5mm
- Measures a range from 1 A to 5 A AC, reconnectable
- LED indication of the switching state
Информацията за складовите наличности временно не е налична.
Моля, проверете отново по-късно.
€ 156,78
Всеки (ex VAT)
1
€ 156,78
Всеки (ex VAT)
1
Купете в насипно състояние
количество | Единична цена |
---|---|
1 - 4 | € 156,78 |
5+ | € 152,42 |
Технически документи
Спецификации
Brand
Phoenix ContactModule Type
Current Transducer
Input Signal Type
Current
Output Signal Type
Current
Input Range
5A
Output Range
0 → 20mA
Mounting Type
Chassis Mount
Operating Temperature Range
-25 → +60°C
Series
MCR-SLP
Minimum Operating Temperature
-25°C
Maximum Operating Temperature
+60°C
Страна на произход
Germany
Детайли за продукта
MCR-SLP-1-5-UI-0 Current transducer - 2814359
The 2814359 from Phoenix Contact is an MCR passive current measuring transducer used for sinusoidal alternating currents. This transducer can convert AC into analogue signals ranging from 1-20mA or 0-10 V. The module is powered purely through the loop, so no need for any external power. With being loop-powered, this device also mounts on a DIN rail, making it a great addition to your cabinet, making it effortless to convert into analogue signals. Not to mention, 2814359 also has great accuracy with its transmission error only at 0.5%.
Features and benefits:
- Passive currently transformers without any auxiliary power
- Screw connection method accepting wire sizes from 0.2 up to 2.5 mm2
- Limit monitor
- Limit value and alarm suppression time set by two potentiometers
- DIN rail - width of only 22.5mm
- Measures a range from 1 A to 5 A AC, reconnectable
- LED indication of the switching state